Main Features
- Guarantees precise thermal support through a microprocessor based servo controlled system featuring pre warm manual and automatic modes.
- Streamlines clinical workflow utilizing an 8 inch LCD touch screen that displays temperature trends and incorporates an APGAR timer.
- Provides a safe and stable microenvironment using a far infrared ceramic heating tube equipped with comprehensive self testing and failure alarms.
- Accommodates diverse medical procedures easily with a tilt adjustable infant bed and a convenient built in X ray cassette holder.
- Enhances operational convenience featuring a horizontally adjustable heater head adjustable LED observation lighting and multiple storage trays.
Product Description
When outfitting a Neonatal Intensive Care Unit with a dependable Neonatal Radiant Warmer maintaining a stable thermal environment is an absolute priority. The ME-N6 Infant Radiant Warmer utilizes an advanced microprocessor based servo controlled temperature system to deliver precise skin and air temperature regulation. Featuring pre warm manual and automatic modes this Infant Resuscitation Warmer guarantees a safe and cozy microenvironment for fragile newborns.
During critical care moments medical staff can rely on the 8 inch LCD touch screen and integrated APGAR timer to streamline emergency workflows and monitor historical data trends. To build a comprehensive Open Care Infant Warmer system the equipment includes a tilt adjustable infant bed a horizontally adjustable heater head and a built in X ray cassette holder. Choose this versatile medical solution equipped with comprehensive failure alarms and adjustable LED observation lighting to empower healthcare teams and deliver exceptional care right from the first breath.
Technical Specifications
| Model | ME-N6 | Model | ME-N6 |
|---|---|---|---|
| Power supply | AC¹10/220V 60/50HZ | Infant bed tilt angle | ±12° |
| Power Input | ≤850VA | Warm-up time | ≤45min |
| Temp.control mode | pre-war,manual and automatic | Mattress size | 680*540*40mm |
| Skin temp.control range | 32.0℃~38.0℃ | Distance from | 810mm |
| Skin temp.control accuracy | ±0.5℃ | heater to mattress | 810mm |
| Mattress temp.uniformity | ≤2℃ | APGAR timing | 1min,5min,10min.. |
| Air temp.display range | 0~45℃ | Tray size | 325*255mm |
| Over temp.alarm | 38.0℃ | Storage tray size | 520*300mm |
| High mode temp.range | 37.1℃~38.0℃ | Operating conditions | environment temperature 18℃~30℃ |
| High mode temp.alarm | 39.0℃ | Operating conditions | environment relative humidity 30%~75%RH |
| Temp.deviation alarm | ±1.0℃ | Operating conditions | atmospheric pressure 700hpa~1060hpa |
| Temp.display accuracy | ±0.1℃ | Operating conditions | environment air velocity of flow <0.3m/s |